sao虎在线精品永久观看入口_公主被侍卫灌满h_在线无码中文字幕一区_强壮的公么征服我厨房_冰山男总裁屁股夹钢笔开会

| 您的位置:中國制冷網->資料軟件->論文
運行環(huán)境 Win2000/WinXP/Win2003
軟件大小 591.86 KB 軟件授權 免費
軟件語言 簡體中文 軟件類別 國產軟件
更新時間 2010-11-17 21:30:32 下載次數(shù)
評論(0) 發(fā)表評論    
★★★☆☆ ktswj
本軟件詳細描述
摘 要   用于住宅或辦公樓的空調室外機組通常安裝在側墻或屋頂上。由于空調室外冷凝機組釋放的熱量會使上部樓層周圍
環(huán)境空氣溫度升高,這將導致建筑有限空間內溫度的明顯升高,使環(huán)境不舒適度和空調機組的運行能耗增加。室外冷凝機組
離墻的安裝距離是影響機組效率的一個重要因素。 采用flunet軟件研究了高層住宅建筑第一層的室外冷凝機組離墻的安裝距
離對有限空間內流體的流動和溫度分布的影響,得出了不同空間尺寸下室外冷凝機組離墻安裝的最佳距離,為優(yōu)化氣流分布
和提高機組效率提供了有效的技術支持,且對工程實踐具有重要的指導意義。
關鍵詞  高層建筑   室外機組   釋放熱   數(shù)值模擬   安裝位置
 
NUMERICAL SIMULATION ON OPTIMUM INSTALLATION
LOCATION OF OUTDOOR CONDENSING UNITS FOR
AIR-CONDITIONER
Zhang Zhen1
  Tong Lige11
  Yin Shaowu1
  Wang Li
1
  Zhao Jie1
 
Yue Xianfang1
  Zhang Beisheng2
 
(1 Institute of Mechanical Engineering, Beijing University of Science and Technology, Beijing,
100083; 2 BEIJING GAUGING CONSULTANTS CO.,LTD, Beijing, 100089)
 
Abstract    Air-conditioners used in residential or office buildings often have the outdoor condensing units installed at
the sidewalls or on the roofs. As a result of air-conditioner condensing units on the top floors suffering from an elevated
ambient air temperature due to the heat rejected from the condensing units below, it will cause temperature rise in the
con?ned space of a high-rise building, lead to uncomfortable thermal environment and deteriorative performance of the
air-conditioning system. Installation distance from the wall is an important factor that affects the performance of the
air-conditioning system. FLUENT software is applied to simulate the effect of the distance from the sidewall on the
fluid  ?ow and temperature distribution in the con?ned space of the first- storey high-rise residential building. The
minimum recommended installation distance from the sidewall with the different dimensions of the con?ned space is
obtained. The effective technical data can be provided for optimizing air distribution and improving the efficiency of the
air-conditioning system, which is important to engineering practices.
Keywords  High-rise building  Outdoor units  Heat rejection  Numerical simulation  Installation location